Pressure>Transducers>Differential Pressure Transmitter


Look at our page on:

EDD575

Features

  • Turn Down up to 1:16
  • Accuracy better than 0.1%
  • High long-term stability
  • Diff. Pressure range 3.75 mbar...20 bar
  • Line pressure up to 140 bar
  • HART® communication
  • Zero adjustment
  • Damping
  • Robust and modular design
  • Square root output (FKK)
  • Linearisation table (FKK)
  • Analogue or digital display (Option)

The EDD575 differential pressure transmitter accurately measures differential pressure and transmits a 4...20mA/HART® signal based on linear output or square root (FKK).

0.1% accuracy for all configured spans is the standard feature covering differential ranges from 0.0375 bar to 20 bar.

The micro-capacitance silicon sensor element assures this accuracy for all elevated or suppressed measuring ranges without additional adjustment. Silicon has great mechanical properties, such as no hysteresis featuring an excellent repeatability.

The compensation data is stored in the sensor device, making it possible to replace the electronics unit, the HART® communication module and the local indicators without re-calibrating the complete assembly.

The HART® communication module can be configured with a standard HART® communicator.

Analogue and digital indicators can be mounted displaying individual read-outs. The EDD575 is suitable for a wide range of process applications in differential pressure, level and flow measurements.

Differential Pressure Transmitter