These transducers must be adequately earthed to meet EN 61000-6-2.
Specifications
Input
- Pressure Range: 30mbar to 20bar with intermediate ranges to suit application
- Proof Pressure: 1.5 x FS
- Line Pressure: 34bar G maxMechanical Configuration
- Pressure Port: G1/8"AT Internal
- Wetted Parts: Compatible with air, water and oil
- Electrical Connection: 1metre cable
- Approvals: CE
- Weight: 250 gmsPerformance
- Long Term Drift: 0.2% per year typical
- Accuracy: 0.25% FS
- Thermal Error: +1%
- Compensated Temperatures: -20° to 80°C
- Operating Temperatures: -25°C to 85°C
- Zero Tolerance: +0.2% of span
- Span Tolerance: +0.2% of span